MAFT-GUN® MOVAMID (Auto) 1CC and equipment casesMAFT-GUN® MOVAMID (Auto) 1CC and equipment cases

FAT GRAFTING & SOFT TISSUE DISPENSING

MAFT-GUN®MOVAMID (Auto) 1CC

Autologous fat grafting gun kit.

An autologous fat grafting gun kit with an electric motor that advances the piston of a 1 cc syringe for fat grafting and soft tissue filler injection. The upper body detaches for sterilization; the electric handle is processed separately.

Catalog MAFT-GUNLegal documentsTechnical specifications

TECHNICAL SPECIFICATIONS

Technical details of the device kit.

CHARM-MAFTGUN(Auto)-21

Based on Vihan's signed and stamped technical summary dated 27 July 2026.

Download Vietnamese specifications
Intended use

Autologous fat grafting, soft tissue filler injection, and injection of other biocompatible liquid or semi-solid medical materials as professionally indicated.

Contraindications

Do not use with materials not approved under applicable medical regulations, or with allogeneic or xenogeneic fat graft materials.

Professional precautions

A trained physician must perform the procedure under sterile conditions. Use the manufacturer's power adapter with the specified rating. Do not immerse or autoclave the electric handle. Potential complications include vascular occlusion, necrosis, overcorrection, infection, inflammation or surface irregularity.

Device name
Autologous fat grafting gun kit
Model code
CHARM-MAFTGUN(Auto)-21
Compatible syringe volume
1 cc
Input voltage
100–240 V
Input current
0.2–0.4 A
Supply frequency
47–63 Hz
Operating voltage / current
7 V / 0.67 A
Power adapter rating
7 V / 1.71 A
Gun weight
385 g
Dimensions (L × W × H)
153.2 × 155.2 × 34.9 mm
Motor noise level
< 80 dBA
Motor service life
1,000–3,000 hours
Operating temperature
5–35°C
Operating humidity
0–90% RH
Operating pressure
80–106 kPa
Steam sterilization: upper body and cannulas approved for reprocessing
121°C / 30 minutes
MOVAMID Auto electric handle and power connectionMOVAMID Auto electric handle and power connection

MOVAMID AUTO / 01

Electric drive

An integrated drive mechanism

DC power is supplied through an adapter connected to the lower handle. Activating the trigger drives the syringe piston, delivering fat or filler through a dedicated injection cannula to the target tissue.

MOVAMID Auto 1CC output selection mechanismMOVAMID Auto 1CC output selection mechanism

MOVAMID AUTO / 02

4 delivery settings

Select the volume per delivery

The fine-tuning knob selects the volume for each delivery. The settings below are listed on the manufacturer's product page.

  • 1/60 cc
  • 1/90 cc
  • 1/150 cc
  • 1/240 cc
MOVAMID Auto instrument rotation and orientationMOVAMID Auto instrument rotation and orientation

MOVAMID AUTO / 03

360° orientation

12 directional settings

The 360° rotating holder adjusts the direction of the fat injection cannula side port, with 12 selectable orientations.

MOVAMID Auto 1CC alloy bodyMOVAMID Auto 1CC alloy body

MOVAMID AUTO / 04

Alloy instrument body

Medical-grade alloy

A medical-grade alloy body combines the metal instrument structure with the MOVAMID Auto electric operating system.

Separating the MOVAMID Auto upper body and handleSeparating the MOVAMID Auto upper body and handle

MOVAMID AUTO / 05

Detachable construction

Separate the upper body and electric handle

The upper and lower body separate according to the operating procedure, allowing the instrument section to be handled independently of the electric grip after use.

DPB Cannula fitting on MOVAMID Auto 1CCDPB Cannula fitting on MOVAMID Auto 1CC

MOVAMID AUTO / 06

Injection cannula holder

DPB Cannula 16G, 18G

The dedicated holder positions and secures the cannula. The 1CC model is compatible with 16G, 18G DPB Cannula.

MOVAMID Auto instrument and electric handle casesMOVAMID Auto instrument and electric handle cases

MOVAMID AUTO / 07

Separate cleaning procedures

Upper body and cannulas: 121°C / 30 minutes

Clean and dry the upper body and cannulas approved for reprocessing before steam sterilization at 121°C for 30 minutes, following the device instructions. This cycle does not apply to single-use DPB Cannula. Wipe the lower electric handle with 75% alcohol; do not immerse it or autoclave it. Enclose the handle in a sterile sleeve during use.

MOVAMID Kit Auto 1CC accessoriesMOVAMID Kit Auto 1CC accessories

MOVAMID AUTO / 08

Instrument case & accessories

MOVAMID Kit (Auto) 1CC

The kit includes syringe caps for fat centrifugation, a syringe transfer adapter, blunt side-port fat injection cannulas, a local anesthetic infiltration cannula, a 2.5 mm liposuction cannula with stylet and a centrifuge tube rack. The upper-body case is separate from the lower handle and power-adapter case.

DPB Cannula packs and blunt cannula sizesDPB Cannula packs and blunt cannula sizes

MOVAMID AUTO / 09

DPB Cannula

Single-use blunt cannula

DPB Cannula is available in 14G, 16G, 18G and 21G. Select a size compatible with your MOVAMID model. These are separately purchased consumables, outside the standard instrument case configuration.

Explore the other modelMAFT-GUN® MOVAMID (Auto) 10CC

For professional use. Selection, operation, cleaning and sterilization must follow the instructions supplied with the device.

Product reference: Dermato Plastica Beauty

Contact Vihan

Choose how you would like to contact us.

Call Vihan0903 717 689Chat on ZaloVihan product supportEmail Vihaninfo@vihan.vn